Pachem-CR-1021_TR

Multifunctional Package for Water Cooloing Systems

General Information:

Pachem-CR-1021_TR is an innovative, multi-functional corrosion -scale inhibitor- dispersant package used for water cooling installations in the refinery, mining and energy industries, which is based on phosphonates, polymers and copolymers as well as environmentally friendly corrosion inhibitors. Pachem-CR-1021_TR prevents the formation and precipitation of inorganic salts, mainly calcium carbonates. It disperses precipitated carbonates. Prevents a pitting, cavitation and crevice corrosion as well as deposit attack. It is effective in a wide range of parameters for the circulating water parameters. It has low environmental impact. Does not contain inorganic phosphates. Does not contain carcinogenic compounds, i.e. nitrites, chromates, hydrazine. Stable in contact with oxidizing biocides.

Typical Physical and Chemical Properties:

ParameterUnitValueTest method
Colour, at 20 ºC  - Amber PB-01 - Edition 1
Density at 15 ºC  kg/m3 800 - 900 PN-EN ISO 12185:2002
Pour Point ºC < -30 PN-EN ISO 3016:2005
Flash Point ºC < 23 PN-EN ISO 2719:2016
Vsicosity at 20 ºC mm2/s < 5 PN-EN ISO 3104:2004
Water solubility - Very good Visual inspection
Solubility in hydrocarbons - Partial Visual inspection

Application:

Dosage of Pachem-CR-1021_TR is recommended to ensure the durability of steel elements of heat exchangers, which life without adequate protection against corrosion and stone is 0.5 - 2 years. The use of Pachem-CR-1021_TR will result in :
- extending the life of protected installations and devices
- limiting of repair and cleaning costs
- reduction of downtime during repair

Treat rate:

The multifunctional corrosion-scale inhibitor-dispersant Pachem-CR-1021_TR package should be dosed continuously, in proportion to the amount of water supplied to the cooling system. It is recommended to keep the Pachem-CR-1021_TR concentration at 50-250 ppm in the cooling system (recommended dose is 100 ppm). There is not recommended the dosage above 250ppm. The dosing level depends on the quality of refilling water and the quality of the water in the cooling system. The higher the general hardness and the carbonate hardness, the higher is the dosage.
It is recommended to take water from the cooling system and rfilling water before dosing in order to carry out detailed tests and then select the dosage correctly. Before dispensing, the Pachem-CR-1021_TR package can be diluted with demineralized water.

Packaging:

Pachem-CR-1021_TR is available in 200 liter drums or 1000 liter IBCs. Other packagings are available on request.

MSDS card (for registered clients only):

Attention: Properties and data provided above are for information purposes only. Detailed properties of the product and guaranteed levels of efficiency are given to our clients in Technical Data Sheets.